| Optómetros |
| Los optómetros
son instrumentos de medida de radiación
óptica que se pueden adaptar
para medidas fotométricas,
radiométricas, de colorimetría,
y para aplicaciones en transmisión
y/o reflexión.

|
| Optómetros de mano |
P-9710
- Single-channel / 16-mode Universal
Optometer
• Compact Single-Channel
Meter for Service and Laboratory
Use
• Universal Use in Any Light
Measurement Application
• Calibration Data Connector
for Simple & Unlimited Detector
Exchange
• Measurement of DC, AC and
Flash Signals
• Short Slew-Rate for fast
Measurements
• 100 µs Fast Sampling
Rate
• Adjustable Integration Time
from 100 µs to 6 s
• Wide Detector Signal Dynamic
Range from 0.1 pA to 2 mA
• RS232 Interface for Remote
Control Operation
• Optional Windows Software
• P-9710-2 Version available
for single Pulse Energy Measurements
(> 1 µs) |
|
X11
- 4-channel/ 4-mode Universal Optometer
/ Color Meter
• Field Service and Lab Meter
• Multiplex Operation of up
to 4 Detectors
• 0.1 pA Resolution (-LS Version)
• 20 ms to 1 s Adjustable
Integration Time
• Photometric and Radiometric
Mode
• Color and Color Temperature
Mode
• USB Interface
• Battery & AC Operation
(via USB) |


|
| Optómetros de banco |
P-2000
- 2-channel Universal Optometer
• Universal 2-Channel Bench-top
Optometer
• Compatible with all Gigahertz-Optik
Detectors
• Unlimited Detector Exchange
by Calibration Data Connector (-2)
• 15 Menu Controlled Operation
Modes including DC, AC , Pulse &
Ratio
• 0.1 pA to 2 mA Current Measurement
Range
• 100 µs Max. Sampling
Rate
• Remote Control Operation
by RS232 & IEEE488 Interface
• Analog Output
|
|
P-9801
- 8-channel Universal Optometer
* Simultaneous Operation of up
to 8 Light Detectors
* Simultaneous Operation of up to
2 Luminous Color Detectors
* 0.1 pA to 2 mA Signal Range
* Integrating Time 1 ms to 10 s
* 10 Operation Modes including Color
Measurements
* IEEE488 & RS232 Remote Control |


|
P-9802
- Multi-channel (2 to 36) Universal
Optometer
• Multi-channel Bench-top
Optometer for Process Integration
• Variable Set-up of 2 to
36 Measurement Channels
• Simultaneous Operation of
up to 12 Detectors
• Can be used with all Gigahertz-Optik
Light Detectors
• Measurement of DC and AC
Signals
• 1 pA to 200 µA Signal
Range
• Adjustable Integration Time
from 20 ms to 4 s
• CW and Dose Operation Modes
• RS232 Remote Control
• OS-P9802 Software for Data
Readout and Excel Transfer
|
|
TR-9600-
Pulse-form Analyzer
* Single Channel Bench-top Instrument
available in two Versions
TR-9600-1: with 1 µs slew
rate signal amplifier
TR-9600-2: with 100 ns slew rate
signal amplifier
* Single Light Flash & Pulse
Train Measurement
* Measurement in Absolute Radiometric
& Photometric Quantities
* Data-logger with 10 Mega Sample
/ sec Rate
* Transient Recorder with 512 000
Sample Capacity
* Remote Control Gain Selection
* Remote Control Trigger Mode Selection
* IEEE488 & RS232 Remote Control
* Windows Based Software |


|
| Amplificadores |
P-9202
- Amplifiers
* Current to Voltage Amplifiers
available in five different Versions:
High-speed Current to Voltage Amplifier
* P-9202-4: Sensitivity Range from
300 nA/V to 1 mA/V
* P-9202-7: Sensitivity Range from
11 µA/V to 1 mA/V
High-gain Current to Voltage Amplifier:
* P-9202-5: Sensitivity Range from
100 pA/V to 1 mA/V
* P-9202-6: Sensitivity Range from
10 pA/V to 100 µA/V
* P-9202-8: Sensitivity Range from
100 pA/V to 1 mA/V
* Bandwidth up to 330 kHz
* Eight Gain Steps
* Easy to Use
* Metal Shielded Package
* Remote Control Interface with
Opto-Coupler
* AC operation |
|
| Fotómetros, Radiómetros, Colorímetros, Dosímetros |
X91
- Photometer / Lux Meter for Illuminance/Luminance
Measurements
• Illuminance (lx) and/or
Luminance (cd/m²) Photometer
• DIN Class B Parameters
• Compact Size for Mobile
Use
• Easy to Use
• Large Size Display
• High Realibility
• Economical Price
• Ergonomic Design
• OEM Labeling
|
|
X92
- High Power Radiometer for UV-Curing/Processing
Measurements
• 0.1 mW/cm² to 35000
mW/cm² measurement Range
• 100°C Sensor Operating
Temperature (200°C peak)
• 3 package Design: RCH-0xx
with flexible Light Guide, RCH-1xx
with rigid Light Guide and RCH-5xx
with in-line Detector.
• 3 spectral Sensitivities:
UV-A (RCH-x08), BLUE (RCH-x09) and
Broadband UV (RCH-x06) Responsivity
• Ex: RCH-106
• Cosine Correction
• Power Measurement Mode with
Snapshot Hold Function
• Dose Measurement Mode
• Traceable Calibration
• Easy to Use
• Economical Price |


|
X93
- Radiometer for Laser Power and
Laser Stray-Light Measurements
• Economical Laser Power
Meter
• Laser Power up to 100 mW
• 7 mm dia. Flat-field Detector
400 to 1100 nm: LP-9901
• Integrating Sphere Detector
400 to 1100 nm: LP-9910
• CW Snapshot Hold Function
• Compact Size
• Easy to Use
• Economical Price
• Battery Operation
• RS232 Interface Option
|
|
X94
- Radiometer / Photometer for Radiant
Power and Luminous Flux Measurements
• Power Meter for Light-Guides,
Endoscopes, LED‘s, Spot-sources
• Detectors with Integrating
Sphere for Beam Shape Independent
Measurements
• Radiometric and/or Photometric
Characteristics
• CW Snapshot Hold Function
• Easy to Use
• Economical Price
• Battery Operation |


|
X96
- Radiometer for UV-A, UV-B and
UV-B311 Phototherapy Measurements
• Broadband UV-A and UV-B
Responsivity
• Calibration for Narrowband
UV-B311 UV Sources
• Cosine Correction
• Power Measurement Mode*
with Auto-range
• CW Mode with Snapshot Hold
Function
• Dose Measurement Mode
• Easy to Use
• Economical Price
• Battery Operation
|
|
X97
- Radiometer for Irradiance Measurements
• Hand-held Single Channel
Irradiance Meter
• Wide Range of UV-VIS-NIR
Polychromatic Irradiance Detector
Heads
• Measurement of DC and AC
Signals
• Peak Value Hold Funktion
• Signal Range from 0.1 pA
to 200 microA with 7 Gain Ranges
• Automatic or Manual Gain
Range selection
• Easy to use
• Offset Compensation
• Compact Size
• Battery Operation
• RS232 Interface |


|
X98
- Radiometer / Lux Meter for Measurements
in NDT and Photostability Testing
• Hand-Held Dual-channel
Meter for Field Service and Laboratory
Use
• Flat UV-A & DIN Class
B Lux Detector: XD-9502
• Quick & Easy Handling
• Economical Price
• RS232 Remote Control or
Data Collection
• Traceable Calibration
• Large LCD
• Dose Measurement Mode
• Wide Measurement Range
|
|
X910
- Radiometer for Radiant Power Measurements
in Telecommunication Testing
• Economical Price
• Readout in dBm
• Power Range from 10 dBm
to -60 dBm
• Spectral Range 850 to 1700
nm
• High Performance Integrating
Sphere
• No Beam Mis-alignment Error
• No Polarization Effected
Error
• No Beam `Bounce-Back` Error
• No Detector Saturation |


|
X911
- Radiometer for UV-C (254 nm) Irradiance
Measurements
• Hand-held Single Channel
UV-C Irradiance Meter
• Measurement Range from 0.05
to 1000 mW/cm² with 0.001 mW/cm²
Resolution
• Solid-state Detector with
Cosine Correction: UV-3718
• Monochromatic Calibration
at 254 nm
• CW Mode with Snapshot Hold
Function
• Solar Blind UV-C Responsivity
• Battery Operation, RS232
Interface Option
• Waterproofing Option
|
|
| X912
- Radiometer for ACGIH/ICNIRP Effective
Irradiance Hazard Measurement
• Hand-held Single Channel
UV Hazard Meter
• ACGIH Effective Irradiance
Measurement
• Measurement Range 0.5 to
999 999 µW/cm² with 0.01
µW/cm² Resolution
• Traceable Calibration of
the ACGIH Sensitivity
• Solid-state Detector with
Cosine Corrected Field of View:
UV-3708
• CW Mode with Snapshot Hold
Function
• Dose Measurement Mode
• Easy to use
• Battery Operation, AC option
available
• RS232 Remote Control Operation
• Waterproofing Option |


|
PT-9610
- Laser Qualification Optometer
for Laser Power and Noise Measurement
# Hand-held Portable Single Channel
Laser Qualification Meter for
- Laser Power Measurement from 350
to 1100 nm, up to 90 mW
- Effective and Peak Noise Value
Analysis
# Effective Values with Wide Band,
Low Frequency and High Frequency
Selection
# Peak Values with Positive Peak,
Negative Peak and Peak-to-Peak Selection
# Calibration at Common Laser WaveLengths
# 90 mW max. Power
# 0.1 µW max. Resolution
# Optometer delivered with PD-1
Detector Head
# Service or Production Use
# Battery or AC Operation
|
|
HCT-99
- Luminous Color Meter
• Precision Hand-held Color
and Illuminance Meter (lx)
• Real Xshort, Xlong, Y and
Z Tristimilus Detector
• x,y and u‘,v‘
Chromaticity Coordinates
• Correlated Color Temperature
(K)
• Delta uv deviation from
blackbody sources
• Backlit Display
• USB Intercace
• Economical Price
• OEM Labeling
• Battery Operation |


|
X-2000
- Personal Dosimeter for Photobiological
and UV Hazard Applications
• Personal Datalogger
• One or Two Channel Models
(11 different Combinations)
• ACGIH/ICNIRP, Erythema,
UV-A, UV-B and Illuminance Detectors
available
• Cosine Correction
• Large Data Capacity up to
250.000 samples
• Compact and light Weight
(60 g / 0.13 lb)
• Sleep Mode to Conserve Battery
Life
• RS232 Remote Control
• OS-X2000, Windows Compatible
Software |


|
| Fotómetro espectral e integral |
X4
- Light Analyser for Photometry
& Colorimetry
Combined Integral/spectral Light
Analyzer for:
• Precise photometric measurement
• Wide dynamic range photometric
measurement
• Spectral distribution determined
colorimetric quantities
• x,y chromaticity coordinates
& dominant wavelength
• Correlated color temperature
& color rendering index,
• Illuminance & optional
Luminance, Luminous Flux and Luminous
Intensity Capability with accessory
components
• USB interface for remote
control operation,