link gyûjtemény

│  Home  │  Contactar  │ 
                 │  Nosotros     Productos      Fabricantes      Archivos      Downloads      Links      Buscador 
Optómetros

Los optómetros son instrumentos de medida de radiación óptica que se pueden adaptar para medidas fotométricas, radiométricas, de colorimetría, y para aplicaciones en transmisión y/o reflexión.

 

Optómetros de mano

P-9710 - Single-channel / 16-mode Universal Optometer

• Compact Single-Channel Meter for Service and Laboratory Use
• Universal Use in Any Light Measurement Application
• Calibration Data Connector for Simple & Unlimited Detector Exchange
• Measurement of DC, AC and Flash Signals
• Short Slew-Rate for fast Measurements
• 100 µs Fast Sampling Rate
• Adjustable Integration Time from 100 µs to 6 s
• Wide Detector Signal Dynamic Range from 0.1 pA to 2 mA
• RS232 Interface for Remote Control Operation
• Optional Windows Software
• P-9710-2 Version available for single Pulse Energy Measurements (> 1 µs)

 

X11 - 4-channel/ 4-mode Universal Optometer / Color Meter

• Field Service and Lab Meter
• Multiplex Operation of up to 4 Detectors
• 0.1 pA Resolution (-LS Version)
• 20 ms to 1 s Adjustable Integration Time
• Photometric and Radiometric Mode
• Color and Color Temperature Mode
• USB Interface
• Battery & AC Operation (via USB)

Optómetros de banco

P-2000 - 2-channel Universal Optometer

• Universal 2-Channel Bench-top Optometer
• Compatible with all Gigahertz-Optik Detectors
• Unlimited Detector Exchange by Calibration Data Connector (-2)
• 15 Menu Controlled Operation Modes including DC, AC , Pulse & Ratio
• 0.1 pA to 2 mA Current Measurement Range
• 100 µs Max. Sampling Rate
• Remote Control Operation by RS232 & IEEE488 Interface
• Analog Output

P-9801 - 8-channel Universal Optometer

* Simultaneous Operation of up to 8 Light Detectors
* Simultaneous Operation of up to 2 Luminous Color Detectors
* 0.1 pA to 2 mA Signal Range
* Integrating Time 1 ms to 10 s
* 10 Operation Modes including Color Measurements
* IEEE488 & RS232 Remote Control

P-9802 - Multi-channel (2 to 36) Universal Optometer

• Multi-channel Bench-top Optometer for Process Integration
• Variable Set-up of 2 to 36 Measurement Channels
• Simultaneous Operation of up to 12 Detectors
• Can be used with all Gigahertz-Optik Light Detectors
• Measurement of DC and AC Signals
• 1 pA to 200 µA Signal Range
• Adjustable Integration Time from 20 ms to 4 s
• CW and Dose Operation Modes
• RS232 Remote Control
• OS-P9802 Software for Data Readout and Excel Transfer

TR-9600- Pulse-form Analyzer

* Single Channel Bench-top Instrument available in two Versions
TR-9600-1: with 1 µs slew rate signal amplifier
TR-9600-2: with 100 ns slew rate signal amplifier
* Single Light Flash & Pulse Train Measurement
* Measurement in Absolute Radiometric & Photometric Quantities
* Data-logger with 10 Mega Sample / sec Rate
* Transient Recorder with 512 000 Sample Capacity
* Remote Control Gain Selection
* Remote Control Trigger Mode Selection
* IEEE488 & RS232 Remote Control
* Windows Based Software

Amplificadores

P-9202 - Amplifiers

* Current to Voltage Amplifiers available in five different Versions:
High-speed Current to Voltage Amplifier
* P-9202-4: Sensitivity Range from 300 nA/V to 1 mA/V
* P-9202-7: Sensitivity Range from 11 µA/V to 1 mA/V

High-gain Current to Voltage Amplifier:
* P-9202-5: Sensitivity Range from 100 pA/V to 1 mA/V
* P-9202-6: Sensitivity Range from 10 pA/V to 100 µA/V
* P-9202-8: Sensitivity Range from 100 pA/V to 1 mA/V

* Bandwidth up to 330 kHz
* Eight Gain Steps
* Easy to Use
* Metal Shielded Package
* Remote Control Interface with Opto-Coupler
* AC operation

Fotómetros, Radiómetros, Colorímetros, Dosímetros

X91 - Photometer / Lux Meter for Illuminance/Luminance Measurements

• Illuminance (lx) and/or Luminance (cd/m²) Photometer
• DIN Class B Parameters
• Compact Size for Mobile Use
• Easy to Use
• Large Size Display
• High Realibility
• Economical Price
• Ergonomic Design
• OEM Labeling

X92 - High Power Radiometer for UV-Curing/Processing Measurements

• 0.1 mW/cm² to 35000 mW/cm² measurement Range
• 100°C Sensor Operating Temperature (200°C peak)
• 3 package Design: RCH-0xx with flexible Light Guide, RCH-1xx with rigid Light Guide and RCH-5xx with in-line Detector.
• 3 spectral Sensitivities: UV-A (RCH-x08), BLUE (RCH-x09) and Broadband UV (RCH-x06) Responsivity
• Ex: RCH-106
• Cosine Correction
• Power Measurement Mode with Snapshot Hold Function
• Dose Measurement Mode
• Traceable Calibration
• Easy to Use
• Economical Price

X93 - Radiometer for Laser Power and Laser Stray-Light Measurements

• Economical Laser Power Meter
• Laser Power up to 100 mW
• 7 mm dia. Flat-field Detector 400 to 1100 nm: LP-9901
• Integrating Sphere Detector 400 to 1100 nm: LP-9910
• CW Snapshot Hold Function
• Compact Size
• Easy to Use
• Economical Price
• Battery Operation
• RS232 Interface Option

X94 - Radiometer / Photometer for Radiant Power and Luminous Flux Measurements

• Power Meter for Light-Guides, Endoscopes, LED‘s, Spot-sources
• Detectors with Integrating Sphere for Beam Shape Independent Measurements
• Radiometric and/or Photometric Characteristics
• CW Snapshot Hold Function
• Easy to Use
• Economical Price
• Battery Operation

X96 - Radiometer for UV-A, UV-B and UV-B311 Phototherapy Measurements

• Broadband UV-A and UV-B Responsivity
• Calibration for Narrowband UV-B311 UV Sources
• Cosine Correction
• Power Measurement Mode* with Auto-range
• CW Mode with Snapshot Hold Function
• Dose Measurement Mode
• Easy to Use
• Economical Price
• Battery Operation

X97 - Radiometer for Irradiance Measurements

• Hand-held Single Channel Irradiance Meter
• Wide Range of UV-VIS-NIR Polychromatic Irradiance Detector Heads
• Measurement of DC and AC Signals
• Peak Value Hold Funktion
• Signal Range from 0.1 pA to 200 microA with 7 Gain Ranges
• Automatic or Manual Gain Range selection
• Easy to use

• Offset Compensation
• Compact Size

• Battery Operation

• RS232 Interface

X98 - Radiometer / Lux Meter for Measurements in NDT and Photostability Testing

• Hand-Held Dual-channel Meter for Field Service and Laboratory Use
• Flat UV-A & DIN Class B Lux Detector: XD-9502
• Quick & Easy Handling
• Economical Price
• RS232 Remote Control or Data Collection
• Traceable Calibration
• Large LCD
• Dose Measurement Mode
• Wide Measurement Range

X910 - Radiometer for Radiant Power Measurements in Telecommunication Testing

• Economical Price
• Readout in dBm
• Power Range from 10 dBm to -60 dBm
• Spectral Range 850 to 1700 nm
• High Performance Integrating Sphere
• No Beam Mis-alignment Error
• No Polarization Effected Error
• No Beam `Bounce-Back` Error
• No Detector Saturation

 

X911 - Radiometer for UV-C (254 nm) Irradiance Measurements

• Hand-held Single Channel UV-C Irradiance Meter
• Measurement Range from 0.05 to 1000 mW/cm² with 0.001 mW/cm² Resolution
• Solid-state Detector with Cosine Correction: UV-3718
• Monochromatic Calibration at 254 nm
• CW Mode with Snapshot Hold Function
• Solar Blind UV-C Responsivity
• Battery Operation, RS232 Interface Option
• Waterproofing Option

X912 - Radiometer for ACGIH/ICNIRP Effective Irradiance Hazard Measurement

• Hand-held Single Channel UV Hazard Meter
• ACGIH Effective Irradiance Measurement
• Measurement Range 0.5 to 999 999 µW/cm² with 0.01 µW/cm² Resolution
• Traceable Calibration of the ACGIH Sensitivity
• Solid-state Detector with Cosine Corrected Field of View: UV-3708
• CW Mode with Snapshot Hold Function
• Dose Measurement Mode

• Easy to use
• Battery Operation, AC option available
• RS232 Remote Control Operation
• Waterproofing Option

PT-9610 - Laser Qualification Optometer for Laser Power and Noise Measurement

# Hand-held Portable Single Channel Laser Qualification Meter for
- Laser Power Measurement from 350 to 1100 nm, up to 90 mW
- Effective and Peak Noise Value Analysis
# Effective Values with Wide Band, Low Frequency and High Frequency Selection
# Peak Values with Positive Peak, Negative Peak and Peak-to-Peak Selection
# Calibration at Common Laser WaveLengths
# 90 mW max. Power
# 0.1 µW max. Resolution
# Optometer delivered with PD-1 Detector Head
# Service or Production Use
# Battery or AC Operation

HCT-99 - Luminous Color Meter

• Precision Hand-held Color and Illuminance Meter (lx)
• Real Xshort, Xlong, Y and Z Tristimilus Detector
• x,y and u‘,v‘ Chromaticity Coordinates
• Correlated Color Temperature (K)
• Delta uv deviation from blackbody sources
• Backlit Display
• USB Intercace
• Economical Price
• OEM Labeling
• Battery Operation

 

X-2000 - Personal Dosimeter for Photobiological and UV Hazard Applications

• Personal Datalogger
• One or Two Channel Models (11 different Combinations)
• ACGIH/ICNIRP, Erythema, UV-A, UV-B and Illuminance Detectors available
• Cosine Correction
• Large Data Capacity up to 250.000 samples
• Compact and light Weight (60 g / 0.13 lb)
• Sleep Mode to Conserve Battery Life
• RS232 Remote Control
• OS-X2000, Windows Compatible Software

Fotómetro espectral e integral

X4 - Light Analyser for Photometry & Colorimetry


Combined Integral/spectral Light Analyzer for:

• Precise photometric measurement
• Wide dynamic range photometric measurement
• Spectral distribution determined colorimetric quantities
• x,y chromaticity coordinates & dominant wavelength
• Correlated color temperature & color rendering index,
• Illuminance & optional Luminance, Luminous Flux and Luminous Intensity Capability with accessory components
• USB interface for remote control operation,
• Windows based software.

 

 


Lasing, S.A.  2005.  Todos los derechos reservados.    
Design downloaded from FreeWebTemplates.com